RD-Sunguard
Technical sheetHigh performance solar and heat reflective Cool Roof coating with exceptional properties.
RD-Sunguard is applied as a topcoat on all roofing and anti-corrosion coating systems from the RD Coatings range.
A thin layer will allow the surface to reflect solar rays and reduce heat transfer through it.
This technical paint is based on highly innovative chemistry that maintains the essential properties required for cool roof coatings for many years.
RD-Sunguard guarantees long-lasting performance, whether it's energy savings, improved thermal comfort, or better preservation of materials.
BENEFITS:
1. Lower the energy bill of buildings as less energy is used to cool the inside
2. Increase the productivity of solar panels on roofs
3. Reduce Urban Heat Island Effect (UHI) and lower the Carbon Footprint
4. Better thermal comfort by decreasing by several degrees the temperature inside buildings
PROPERTIES
• SRI index ≥ 110 – Solar Reflectance Index - ASTM E 1980
• TSR ≥ 88 % – Total Solar Reflectance - EN 14500 part B and EN 410
• High degree of whiteness and UV resistance
• Maintains its high reflectance value over time
• Excellent dirt pick-up resistance and self-cleaning properties
• Excellent resistance to moss, lichens, and microorganisms.
• Excellent resistance to weathering
• Can be applied as a topcoat on various types of paints and coatings.
• Very easy to apply.
Much more powerful than any ordinary white paint!
Calculate here the amount of paint needed for your project
Technical sheet
Description of the product
USE:
High performance solar reflective coating - Cool Roof system
FEATURES:
Single component water-based solar reflective coating based on new generation of resins enabling the coating to boost its solar reflective properties.
Thanks a high solar reflective index (SRI) over 110, to its special pigmentation, very high UV and excellent dirt pick-up resistance, and self-cleaning properties, RD-Sunguard helps to keep and maintain the surface white and clean to ensure maximum solar and heat reflection over time.
RD-Sunguard is water-based, easy to handle, safe and has no fire risks. It is a fast-drying coating system that greatly reduces downtime during installation and increases on-site labour productivity.
Virtually odour free, it does not affect neighbouring occupants and can therefore be used in occupied buildings.
RD-Sunguard ensures long-lasting performances, whether it is energy savings, better thermal comfort or lower heat effect.
SUBSTRATES:
RD-Sunguard can be used on most kind of surfaces providing first the application of an adequate primer coat (see table with systems)
Systems
BITUMINOUS SURFACES
Sound bituminous roofing > 1 year | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Elastodeck | 800 / 32,5 | 440 / 17,5 | 1,00 Kg / 50 | Contact us for new bituminous roofing. |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
Old bituminous roofing with potential for water infiltration and cracking | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Elastodeck + RD-Roof Fleece | 1600 / 65 | 875 / 35 | 2,00 Kg / 25 | See our "How to renovate a bituminous roofing" solution for details. |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
METAL SURFACES
Sound metal roof with a slope > 4% | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Elastometal | 305 / 12,3 | 175 / 7 | 0,40 Kg / 120 | Consult our "Metal roof renovation" solution for a complete specification. |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
Metal roof with moderate corrosion and slope > 4% | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Elastometal | 460 / 18,5 | 260 / 10,5 | 0,60 Kg / 80 | Consult our "Metal roof renovation" solution for a complete specification. |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
Metal roof with corrosion and/or infiltration problems and a slope > 4% | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Elastometal (système Classique) | 615 / 24,6 | 350 / 14 | 0,80 Kg / 40 | Consult our "Metal roof renovation" solution for a complete specification. |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
Metal objects located in a class C3 corrosive environment | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Monoguard | 200 / 8 | 85 / 3,4 | 0,2 L / 200 | Estimated lifetime > 15 years. |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
Metal objects located in a class C4 corrosive environment | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Monoguard | 150 / 6 | 0,34 l / 117 | Minimum two layers. | |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
Metal objects located in a class C5 corrosive environment | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
First coat | RD-Monoguard | 200 / 8 | 0,47 l / 85 | Minimum two layers. | |
Second coat | RD-Sunguard | 90 / 3,6 | 40 / 1,6 | 0,09 L / 440 |
In case of problematic surfaces like highly corroded, leaking, peeling … refurbish first the surface as described in our Solution pages or contact your RD representative for advice.
Indicated consumption is theoretical and does not consider potential losses during application.
It can also be influenced by the porosity of the substrate.
Application instructions
APPLICATION CONDITIONS:
Ambient temperature: between 12 and 25°C (54 and 77°F).
Relative humidity: maximum 80%
Surface temperature must be minimum 3°C (5°F) above dew point.
APPLICATION MEANS:
Brush, roller or airless (nozzle size: 010–012)
PREPARATION OF THE SUBSTRATE:
The substrate must be clean: dry, degreased and dust free. Non adhering elements such as older coatings must be removed.
Consult our system page for the appropriate primer coat.
DILUTION:
Product is ready-for-use. Dilute with maximum 3% water when applying by airless or in warm weather conditions (> 25°C / > 77°F).
DRYING TIME: (20°C – 68°F)
Touch dry : +/- 30 minutes
Dust free : +/- 45 minutes
Dry : +/- 1 hour
CLEANING OF TOOLS:
Water.
SPECIFICITIES:
Mix well before use.
Technical data
FINISH:
Soft +/- 10% (Gardner 60°)
COLOURS:
White.
DENSITY:
1,10 +/- 0,05 g/cm³
SOLIDS CONTENT:
In weight: 50 %
In volume: 44 %
VISCOSITY:
100-150 P (Brookfield 20RPM)
VOC CONTENT:
< 25 g/L
FLASH POINT:
Not flammable.
STORAGE STABILITY:
Minimum 24 months protected from frost and excessive temperatures in its original closed packaging.
Norms and tests
SOLAR REFLECTIVE INDEX | ASTM E-1980 | > 110 |
TSR – TOTAL SOLAR REFLECTANCE | EN 14500 part B and EN 410 | > 88 % |
NEUTRAL SALTSPRAY | ISO 12944 | - |
ISO 16000-6 / VOC Classification in France |
Safety data
Information related to hygiene and to safety can be found in the Safety Data Sheet available on request.
These specifications are given for information. Since the manufacturer is not able to check the application of the products, he cannot accept any responsibility for it. This technical data sheet replaces all previous editions.
VERS. R023/230620

High performance solar and heat reflective Cool Roof coating with exceptional properties.